ENSolarX ver.5X Full EMS System, Wi-Fi Module, PV and Electrical Energy Control System.
ENSolarX Wi-Fi and management BMS ,of the photovoltaic system, solar inverter and energy storage.
The device enables remote control and configuration of parameters of three devices.
1. Allows you to control and configure the Solar Inverter.
2. Allows you to control and configure the parameters of the energy storage management system BMS (Battery Management System)
Function |
ENSolarX ver 5x Basic |
ENSolarX ver 5x Full |
ENSolarX ver 6x |
---|---|---|---|
Communication with Inverters via RS-232 and RS485 | ✔️ | ✔️ | ✔️ |
Communication with BMS via UART and RS485 | ✔️ | ✔️ | ✔️ |
Built-in WiFi | ✔️ | ✔️ | ✔️ |
Extended WiFi Range | ✔️ | ✔️ | ✔️ |
Improved Operational Stability | ✔️ | ✔️ | ✔️ |
Inputs for 3 Temperature Sensors | ❌ | ✔️ | ✔️ |
Option to Connect an External Energy Meter | ❌ | ✔️ | ✔️ |
Output for Active Balancer Control | ✔️ | ✔️ | ✔️ |
7 SSR Relay Outputs | ❌ | ✔️ | ✔️ |
0-10V Output for Smooth Heater Control | ❌ | ✔️ | ✔️ |
MODBUS for Integration (e.g., Home Assistance) | ❌ | ✔️ | ✔️ |
Configuration via WiFi | ✔️ | ✔️ | ✔️ |
Support for WiFi Relays - SONOFF | ❌ | ❌ | ✔️ |
4 Additional Outputs | ❌ | ❌ | ✔️ |
Support for DEYE, SOFAR Inverters | ❌ | ❌ | ✔️ |
ENSolarX is a Wi-Fi module that allows monitoring and management of the photovoltaic system, solar inverter and energy storage.
The device enables remote control and configuration of parameters of three devices.
1. Allows you to control and configure the Solar Inverter.
2. Allows you to control and configure the parameters of the energy storage management system BMS (Battery Management System)
3. Allows you to control and configure the Rekuset recuperation controller.
4. Device supported by PC or Android phone apps.
5. In the last update, DALY BMS support was added and communication was improved
The ENSolarX device supports Hybrid Solar Inverters by Easun, Powland and BMSs by QUACC, JBD, ANT, DALY, JK (maximum number of cells 16)
The Inverter and BMS with the ENSolarX module are connected via RS-232 buses. The device has 2 separate inputs to operate the Inverter and BMS.
Description of the ENSolarX Management Program
The POWER STATUS tab displays data from the Rekuset driver, if one has been installed. If the RekuSet driver is not installed in the system, this tab will not be supported.
In the POWER STATUS tab, information on the status of atmospheric sensors and data on electricity consumption at a given moment as well as daily and monthly consumption charts are displayed. Data on consumption in this tab are taken from an external meter which sends data via pulse output to the Rekuset controller.
Possibility to control outputs, e.g. garden sprinklers.
The INVERTER tab displays current data from the Solar inverter and the BMS module, such as:
- Current production from Photovoltaic Panels.
- Current consumption.
- Voltage level in the network and at the output of the Inverter.
- Battery voltage.
- Load percentage.
- Inverter Heat Sink Temperature.
- Battery charge level.
- The remaining amount of energy in the batteries
- Charge level of individual cells
- Voltage difference between targets.
- etc..
The REKUSET tab displays current data from the Rekuset recuperation controller.
The OPTIONS tab is the configuration of settings, operating parameters of the Solar inverter and the BMS module.
- Configuring the network connection and the Internet connection of the EnsolarX module.
Below is a schematic diagram of the connections of individual modules.
ENSolarX does not require connection of all modules, it is possible to connect only one device for data analysis, i.e. only the inverter without BMS or BMS without inverter can be connected.
If a given peripheral device is not connected, only data from the unconnected device will not be displayed in the application, while the other components will communicate with the ENSolarX device
Obsługiwane Modele Falowników
Deye SOFAR IGrid
AN-EX-Pro-8200 MPS-V-3200 MPS-V-PLUS DAXTROMN
AXPERT MAX II QOLTEC REVO II GROWATT VOLT
Connecting the Inverter to ENSolarX.
Depending on the inverter you have, the device should be connected via the DB9 9-pin connector or the RJ-45 connector. When ordering, please provide in the comments field information on which Inverter we will connect ENSolarX to attach a connecting cable to the DB9 or RJ-45 connector. The ENSolarX device communicates with inverters using RS-232 communication on the PI30 or Modbus RTU protocol. After connecting the inverter to the ENSolarX device, proper communication is confirmed by both RX TX LEDs located above the connector to the inverter on the ENSolarX board.
DALY BMS connection.
The BMS DALY should be connected to the ENSolarX device via the miniUSB socket, i.e. the miniUSB plug which is connected to the Bluetooth device should be connected to the miniUSB socket of the ENSolarX device. BMS should be automatically detected by ENSolarX as evidenced by both blinking RX and TX diodes above the miniUSB socket on the ENSolarX board
JK BMS connection.
BMS JK to the ENSolarX device should be connected via a 4-pin socket marked in the picture below as RS485. descriptions of this socket differ in individual versions of these BMSs BMS should be automatically detected by ENSolarX, as evidenced by both blinking RX, TX diodes above the miniUSB socket on the ENSolarX board. When ordering, please provide in the comments field information to which BMS we will connect ENSolarX to attach a connecting cable to JK.
QUCC, JBD BMS connection.
BMS QUCC and JBD to the ENSolarX device should be connected via a 4-pin Bluetooth connector, i.e. disconnect the bluetooth board and connect this cable to the connector marked BMS on the ENSolarX board. The BMS should be automatically detected by ENSolarX as evidenced by both blinking RX TX diodes above the miniUSB socket on the ENSolarX board.